Description
OLP – INTERGRATED OVERLOAD PROTECTOR
① | Relief Orifice Diameter |
② | Methods of Adjustment of Relief pressure
No symbol: air adjustment spring adjustment |
③ | Preload pressure ratio
B: 42 No symbol: standard pressure ratio |
④ | Installation direction
L H |
⑤ | Relief pressure range
L H |
Unit: mm
Type |
A | B | C | D | E | F | G | H | PAA |
0LP8/0LP12 |
102 | 79.4 | 282 | 68 | 68 | 112 | 42 | 52 | Rc1/4 |
OLP20 | 121 | 310 | 88 | 88 | 117 | 50 | 70 |
Rc1/4 |
|
0LP25 | 121 | 310 | 88 | 88 | 117 | 50 | 70 |
Rc1/4 |
Unit: mm
Type |
PAS | K | A1 | A2 | W | O | S | P | T |
OLP8/0LP12 |
Rc1/8 | 121 | Rc1/2 | 8 | 11 | 98 | 53 | 6-7 | 15-20 |
0LP20 | 135 | Rc3/4 | 20 | 14 | 85 | 88 | 6-7 |
20-25 |
|
0LP25 | 135 | Rc1 | 25 | 14 | 85 | 88 | 6-7 |
25-30 |